HEAT PUMPS AND REVERSIBLE UNITS

HTE heat pump exchangers are designed for the production of chilled water or heated water by reversing fluid side and air side to meet every need of installation and management of the plant. The focus is on the energy consumption of air conditioning equipment, HVAC systems and hygrometric comfort too, is becoming increasingly important. That's why the ventilated the HTE units for heat pump application are designed to provide maximum energy efficiency at both, full load EER and partial load ESEER. The circuiting is already designed and optimized for these operating conditions. This is a good indicator to understand how HTE actively pursues the policy of energy saving.

A wide range of products and possible configurations of heat pump exchangers: [Table], [V-Form] [Magnum], [H-Flow], [Jumbo], [X-cross] and customized products as well. The construction can be in mono and multi-bank, further customization functional to your needs allows you to find the best balance between thermal capacity conditions, acoustic performance and systemic solutions, guaranteed by the usual HTE quality.

We offer special versions of compact space-saving fans, applications with high voltage, 60 Hz, EC brushless and special versions according to ATEX regulations. You can profit from solutions for OEM´s or the B2B market to reduce the construction lead-time of the water chiller, both for the production of domestic hot water or cold water as needed. Exchangers with geometries suitably designed for low pressure drops on the air side, reducing the formation of ice on the fins and consequently reducing the by-pass factor, obtaining an improvement of the efficiency and of power consumption.

Equipment and accessories can be integrated on request.

ADVANTAGES OF HEAT PUMPS:

  • ENVIRONMENTALLY FRIENDLY: The heat pump technology is clean, has no direct CO2 emissions. 
  • ECOLOGICAL: The driving energy of the heat pumps is only electric energy consumption. 
  • Large heat exchange surface 
  • High ESEER (Eurovent benchmark for partial loads) 
  • Annual energy consumption is lower than 50% compared to traditional heating systems 
  • Noise reduction with electronically commutated EC fans (optional) 
  • Compact and space-saving versions available
  • Centralized supervision (Optional)

Features

Data sheet
Fittings
Generality
Configurations XXX models in catalogue for the XXX serie;
Customized solutions;
Special materials available;
Surface protection treatments;
Switchboards and control logics
Coils Coppers pipes with 10mm, 12mm and 16mm diameter;
Aluminium fins with stackered tube geometrie or alligned with diameters between 1,6 mm to 6 mm;
In standard configuration getween 2 and 6 rows;
Floating side support to allow a better thermal expansion
Structure and cover panels Standard execution with aluminium cover panels;
Fan panels made out of a signle metal sheet;
Stainless steel brackets;
Stainless steel screws and bolts for every removable element;
Self-supporting frame (standard for Jumbo and Magnum, for Table units over 600 mm coil length)
Ventilation Fan diameter between 500 and 1.000 mm;
5 power levels for each diameter in standard configuration;
AC 400V 3̴~ (3-phase) or 200V 1~ (single phase) motors, both for 50Hz;
Upon request 60 Hz, EC-brushless or ATEX versions.
Materials
Fins Tubes Manifolds Metal sheets
Al - Aluminium Standard Non disponibile Non disponibile Standard
Al-P Prepainted aluminium Optional Non disponibile Non disponibile Optional
Al-H Hydrofillic aluminium Optional Non disponibile Non disponibile Non disponibile
Cu - Copper Optional Standard Standard Optional
Ot - Brass Non disponibile Non disponibile Non disponibile Optional
Hot bath zinc steel Non disponibile Non disponibile Non disponibile Optional
Stainless steel Non disponibile Optional Optional Optional
Legenda StandardStandard
OptionalOptional
Not availableNot available
Treatments
Protecting surface treatment of the exchanger element Blygold®
Electrolitic zinc coating
Cataforesis
Fin Guard Silver®
Epoxy coating
Cover panels Special paints according to RAL specifications
Fans
All H.T.E. units are equipped with high efficiency multiple wing fans according to the eco-compatible directive UE nr. 327/2011. The electric motors are thermally protected with IP54 protection class, IP55 according to IEC/EN 60529/ DIN 40050.
The axial fans with external rotor are of the service-free type, with hermetic bearings according to DIN 6252 with lifetime lubrication, statically and dynamically trimmed according to ISO 1940/1.
The windings have different isoltation class, varying between the standarf F class, up to H class for particularly demanding applications.
The functionning limits are between -30°C and +60°C for the standard motor configuration. Other motors are available upon request.
The three-phase motors are ready for the double connection (star, delta or with switching device).
All fans motors are designed to be connected to a tension or a frequency regulation device, to control rotation speed and noise level.
There are 5 different performance sizes at disposal, ensuring excellent performances through the combination of installed power, noise level and respect of the declared consumption.
Optional • Cabled fans ready for the connection on a contact board according to EN 60204-1 rule;
• 60Hz versions;
• Special voltages;
• According to ATEX-regulations;
• In pushing or reversible version;
• With EC-bruschless electronic modulating motors;
• Centrifugal fans;
• Regulation systems;
• HTE Process Control Manager
According to the type of ventilator the motor data may vary.
Please remark that the energy consumption will vary in function of the air temperature and the load conditions.
We reserve ourselves the right to use fans made by different manufacturers. For the corresponding specific electrical data refer yourself to the type of unit or fan model.
Accessories
Hydraulics • Special hydraulic components (valves, fittings, flanges, rotalock or victaulic connections, compensators, temperature or pressure indicators ....)
• Customized hydraulic or refrigerant connections an particular solutions
• Multiple circuit executions;
• Adiabatic misting system (connected to hydrofillic fins);
•PED system with adiabatic panels;
• UV sterilizing lamp;
• Pump stations with stainless steel rotor and cochlea´s single- or multiple pumps;
Electrics, control and regulation • Run switches;
• Cabling in terminal box (EN 60204-1);
• Cabling in switchbox (EN 60204-1);
• Motor protection device with thrmal contact;
• Triac fan speed regulator;
• Frequency control and sinus-filters;
• HTE Process Control Manager;
Structural components • Antivibrtion dampeners;
• Customized lifting brackets;
•Self-supporting frames in pikled welded stainless steel;
• Container installations;
• Custom-made skids;
Reference guidelines
97/23/CE PED
2006/42/CE MD
2002/95/CE RoHS
Direttiva 2004/108/EC EMC
Direttiva 2006/95/CE LVD
Direttiva 2009/125/CE Erp
EN ISO 13857:2008
EN 60204-1
EN 1048:2000
  • DRY. Low sound emission AC or EC fans and unit standard construction (on request wired connection box with terminal plate or wired switchboard)
  • ECO. Low sound emission AC or EC fans with fan speed controls (wired in switchboard)
  • WET. Low sound emission AC or EC fans with fan speed controls and adiabatic water spray system (wired in switchboard)

PRODUCTS

RU_SERIES

[Table]
T1 T11
25kW
T19
600kW
Enter »
* Horizontal construction
* Single fan row
* Single coil
* Vertical air flow
Enter »
T2 T22
50kW
T29
1200kW
Enter »
* Horizontal construction
* Double fan row
* Single coil
* Vertical air flow
Enter »
[V-Form]
V1 V11
25kW
V19
600kW
Enter »
* V-shaped construction
* Single fan row
* Single coil
* Vertical air flow
Enter »
V2 V22
50kW
V29
1200kW
Enter »
* V-shaped construction
* Double fan row
* Double coil
* Vertical air flow
Enter »
[Magnum]
M2 M22
50kW
M29
1200kW
Enter »
* M-type construction
* Double fan row
* 4-coil design
* Vertical air flow
Enter »
[H-Flow]
H1 H11
25kW
H19
600kW
Enter »
* Vertical construction
* Single fan row
* Single coil
* Horizontal air flow
Enter »
H2 H22
50kW
H29
1200Kw
Enter »
* Vertical construction
* Double fan row
* Single coil
* Horizontal air flow
Enter »
[Jumbo]
J1 J11
25kW
J19
600kW
Enter »
* V-shaped construction
* Single fan row
* Double coil
* Vertical air flow
Enter »
J2 J22
50kW
J29
1200kW
Enter »
* V-shaped construction
* Double fan row
* Double V-shaped coil
* Vertical air flow
Enter »
[Xcros]
X2 X22
50kW
X29
1200kW
Enter »
* Modular construction
* Double fan row
* Double coil, V-shaped transverse
* Vertical air flow
Enter »